{"id":83,"date":"2014-07-08T14:34:28","date_gmt":"2014-07-08T12:34:28","guid":{"rendered":"http:\/\/lab.fs.uni-lj.si\/ltbs\/?page_id=83"},"modified":"2026-01-23T10:07:07","modified_gmt":"2026-01-23T08:07:07","slug":"equipment","status":"publish","type":"page","link":"https:\/\/web.fs.uni-lj.si\/licem\/equipment\/","title":{"rendered":"<h2>EQUIPMENT<\/h2>"},"content":{"rendered":"\n<p><strong>The equipment is rented with an operator.<\/strong><\/p>\n\n\n<h3>Hardware<\/h3>\n<ul>\n<li>Greenlight Inovation G60 Fuel Cell Test Station<\/li>\n<li>Baltic FuelCells single unit test cell with integrated current distribution sensor<\/li>\n<li>Ivium XP40 potentiostat, galvanostat and impedance analyzer<\/li>\n<li>On-board (PEMS) particulate counter (Condensation Particle Counter &#8211; CPC method)<\/li>\n<li>On-board (PEMS) particulate matter measuring system (Micro Soot Sensor \u2013 MSS combined with gravimetric method)<\/li>\n<li>2 different On-board emission measurement systems, including raw exhaust gas analyzers (NDIR, NDUV, FID, CLD) &amp; exhaust flow meters<\/li>\n<li><span lang=\"en-US\">Engine dynamometer: 193 kW and 12000 min<\/span><sup><span lang=\"en-US\">-1<\/span><\/sup>\u00a0(max. torque 610 Nm)<\/li>\n<li><span lang=\"en-US\">Engine dynamometer:\u00a0350 kW and 6000 min<\/span><sup><span lang=\"en-US\">-1<\/span><\/sup>\u00a0(max. torque 1850 Nm)<\/li>\n<li>8-Slot FPGA Reconfigurable Chassis Real-Time Controller with multiple high-speed Analog and Digital Inputs and Outputs<\/li>\n<\/ul>\n<ul>\n<li lang=\"en-US\">8-Slot Acquisition System with multiple high-speed Analog and Digital Inputs and Outputs<\/li>\n<li>\n<p style=\"margin-bottom: 0.14in; line-height: 115%;\"><span lang=\"en-US\">6-Channel Solenoid and Piezzo Direct Injector Driver System<\/span><\/p>\n<\/li>\n<li>\n<p style=\"margin-bottom: 0.14in; line-height: 115%;\"><span lang=\"en-US\">Gravimetric Fuel Mass Flow Meter <\/span><\/p>\n<\/li>\n<li>\n<p style=\"margin-bottom: 0.14in; line-height: 115%;\"><span lang=\"en-US\">5\u00a0piezo-electric pressure transducers for in-cylinder pressure measurement<br \/>\n<\/span><\/p>\n<\/li>\n<li>\n<p style=\"margin-bottom: 0.14in; line-height: 115%;\"><span lang=\"en-US\">4-Channel charge amplifier<\/span><\/p>\n<\/li>\n<li>\n<p style=\"margin-bottom: 0.14in; line-height: 115%;\"><span lang=\"en-US\">2 CAM Unit shaft encoders (0,1 deg CA resolution)<\/span><\/p>\n<\/li>\n<li>\n<p style=\"margin-bottom: 0.14in; line-height: 115%;\"><span lang=\"en-US\">Capacitive Sensor for TDC Measurement<\/span><\/p>\n<\/li>\n<li>\n<p style=\"margin-bottom: 0.14in; line-height: 115%;\"><span lang=\"en-US\">3 different size laminar air-mass flow meters up to 0,47 m<\/span><sup><span lang=\"en-US\">3<\/span><\/sup><span lang=\"en-US\">\/s<\/span><\/p>\n<\/li>\n<li>\n<p style=\"margin-bottom: 0.14in; line-height: 115%;\"><span lang=\"en-US\">4 different coriollis mass flow meters up to 87,100 kg\/hr<\/span><\/p>\n<\/li>\n<li>\n<p style=\"margin-bottom: 0.14in; line-height: 115%;\"><span lang=\"en-US\">70-Channel Thermocouple Acquisition System<\/span><\/p>\n<\/li>\n<li>\n<p style=\"margin-bottom: 0.14in; line-height: 115%;\"><span lang=\"en-US\">32-Channel RTD Acquisition System<\/span><\/p>\n<\/li>\n<li>\n<p style=\"margin-bottom: 0.14in; line-height: 115%;\"><span lang=\"en-US\">On-board diagnostics Data Logger<\/span><\/p>\n<\/li>\n<li>\n<p style=\"margin-bottom: 0.14in; line-height: 115%;\"><span lang=\"en-US\">Modular Emission Measurement and Diagnostic System<\/span><\/p>\n<\/li>\n<li>OEM ECU full\u00a0access equipment<\/li>\n<li style=\"list-style-type: none;\"><\/li>\n<\/ul>","protected":false},"excerpt":{"rendered":"<p>The equipment is rented with an operator. Hardware Greenlight Inovation G60 Fuel Cell Test Station Baltic FuelCells single unit test cell with integrated current distribution sensor Ivium XP40 potentiostat, galvanostat and impedance analyzer On-board (PEMS) particulate counter (Condensation Particle Counter &#8211; CPC method) On-board (PEMS) particulate matter measuring system (Micro[&#8230;]<\/p>\n","protected":false},"author":1,"featured_media":0,"parent":0,"menu_order":0,"comment_status":"closed","ping_status":"closed","template":"","meta":{"footnotes":""},"class_list":["post-83","page","type-page","status-publish","hentry"],"_links":{"self":[{"href":"https:\/\/web.fs.uni-lj.si\/licem\/wp-json\/wp\/v2\/pages\/83","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/web.fs.uni-lj.si\/licem\/wp-json\/wp\/v2\/pages"}],"about":[{"href":"https:\/\/web.fs.uni-lj.si\/licem\/wp-json\/wp\/v2\/types\/page"}],"author":[{"embeddable":true,"href":"https:\/\/web.fs.uni-lj.si\/licem\/wp-json\/wp\/v2\/users\/1"}],"replies":[{"embeddable":true,"href":"https:\/\/web.fs.uni-lj.si\/licem\/wp-json\/wp\/v2\/comments?post=83"}],"version-history":[{"count":5,"href":"https:\/\/web.fs.uni-lj.si\/licem\/wp-json\/wp\/v2\/pages\/83\/revisions"}],"predecessor-version":[{"id":1570,"href":"https:\/\/web.fs.uni-lj.si\/licem\/wp-json\/wp\/v2\/pages\/83\/revisions\/1570"}],"wp:attachment":[{"href":"https:\/\/web.fs.uni-lj.si\/licem\/wp-json\/wp\/v2\/media?parent=83"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}